Linijsko pojačalo 39dB/5-860MHz/114dVµV/24-90Vac/15W

Linijsko pojačalo 39dB/5-860MHz/114dVµV/24-90Vac/15W

Kataloški broj: WHO929NG
Dostupnost:
267,49 €
U cijenu je uključen PDV
kom
Kataloški broj:WHO929NG
Šifra artikla:0405018
Barkod:1000000014983
Datoteke:WHO-929NG datasheet.pdf
Opis:WHO-929NG amplifier has been designed for professional multimedia cable TV networks, that uses transmission in reverse path - especially with an HFC architecture.

The device is controlled by universal plugins (attenuators) and single dedicated output path division module. It allows to preserve the highest possible MER and BER parameters for digital signals.

WHO-929NG is equipped with a modern and reliable power supply system that guarantees continuous operation in the most arduous conditions.

Its additional functions include division or splitting signal to another output, embedded ingress filter, and simplified configuration excluding enlarged number of inserts.



Features:

high output level: 114 dBµV (CENELEC 42),
how quality low-noise amplification systems,
designed for transferring high modulations,
easy configuration - universal JXP plug-in modules,
active or passive return path,
remote power supply transferable to any output,
two outputs – division and splitting options,
robust, shock resistant housing.

TECHNICAL PARAMETERS
1) Available version with IP67
Technical parameters may be changed without earlier notice
PARAMETERS WHO-929NG
FORWARD PATH
Frequency range MHz 87, 110…1006
Gain dB 39
Flatness dB ±1
Max. output level (DIN 45004B) dBµV 129
Max. output level CENELEC 42, interstage
equalization 0dB, CTB?-60dB, CSO?-60dBc dBµV 114
Input attenuator dB JXP plug-in: 0…20, step 1
Input equalizer dB JXP plug-in: 0...20, step 1
Interstage adjustment
- attenuator
- equalizer
dB JXP plug-in: 0...20, step 1
JXP plug-in: 0...20, step 1
Interstage equalizer dB JXP plug-in: 0...20, step 1
Test point dB -20 ±1
Noise figure dB < 8
Return loss at all Inputs / Outputs:
- in the frequency range of 5…40MHz
- in the frequency range of 40…1000MHz
dB
dB
18
?18 @ 40MHz -1.5 dB / oct.
RETURN PATH
Frequency range MHz 5…65, 5…85
Gain – measured at amplifier IN / OUT dB -2.5 / 25
Gain characteristic flatness dB ±1
Max. output level - DIN 45004B dBµV 118
Output attenuator dB JXP plug-in: 0...20, step 1
Output equalizer dB JXP plug-in: 0...20, step 1
Test point dB -20 ± 1
Noise figure dB < 6
OTHERS
Operating voltage VAC /Hz 30..90 / 50-60
Power consumption (passive / active return path) W 14 / 16
Current consumption at 30VAC / 90VAC A 0,85 / 0,25
Max. current for every output A 7
Input / output connector (standard) / 5.8” or PG11
Protection class / IP521)
Operational temperature range ?C -20…+55
Weight kg 1.4
Dimensions (W x H x D) mm 219 x 134 x 96
Package / b